English
Language : 

ISL68134_16 Datasheet, PDF (29/50 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68134
VOUT_TRANSITION_RATE (27h)
Definition: Sets the output voltage rate of change during regulation. Changes to this setting require a write to the APPLY_SETTINGS
command before the change will take effect.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: R/W
Default Value: 0064h (10,000µV/µs)
Units: µV/µs
Equation: VOUT_TRANSITION_RATE = (Direct Value)*100
Range: 100µV/µs to 100mV/µs
COMMAND
VOUT_TRANSITION_RATE (27h)
Format
Direct
Bit Position
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Access
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
Two’s Complement Integer
Default Value
0
0
0
0
0
0
0
0
0
1
1
0
0
1
0
0
VOUT_DROOP (28h)
Definition: Sets the output voltage rate of change during regulation. Changes to this setting require a write to the APPLY_SETTINGS
command before the change will take effect.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: R/W
Default Value: 0000h (0µV/A)
Units: µV/A
Equation: VOUT_DROOP = (Direct Value)*10
Range: 0 to 16,000µV/A
COMMAND
VOUT_DROOP (28h)
Format
Direct
Bit Position
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Access
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
Two’s Complement Integer
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Submit Document Feedback 29
FN8817.0
September 28, 2016