English
Language : 

ISL68134_16 Datasheet, PDF (40/50 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68134
STATUS_CML (7Eh)
Definition: Returns a summary of any communications, logic and/or memory errors.
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read Only
Default Value: N/A
COMMAND
STATUS_CML (7Eh)
Format
Bit Field
Bit Position
7
6
5
4
3
2
1
0
Access
R
R
R
R
R
R
R
R
Function
See Following Table
BIT NUMBER
7
6
5
4
3
2
1
0
MEANING
Invalid or unsupported PMBus™ Command was received.
The PMBus™ command was sent with invalid or unsupported data.
A packet error was detected in the PMBus™ command.
Memory fault detected.
Processor fault detected.
Not used
A PMBus™ command tried to write to a read only or protected command, or a communication fault other than the
ones listed in this table has occurred.
A memory or logic fault not listed above was detected.
STATUS_MFR_SPECIFIC (80h)
Definition: Returns the status of specific information detailed below.
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read Only
Default Value: N/A
COMMAND
STATUS_MFR_SPECIFIC (80h)
Format
Bit Field
Bit Position
7
6
5
4
3
2
1
0
Access
R
R
R
R
R
R
R
R
Function
See Following Table
BIT
7:2
Not used
1
OTP NVM memory is full
0
Not used
MEANING
Submit Document Feedback 40
FN8817.0
September 28, 2016