English
Language : 

ISL68134_16 Datasheet, PDF (24/50 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68134
OPERATION (01h)
Definition: Sets enable state when configured for PMBus enable. Sets the source of the target VOUT. The device always acts on faults
during margin. The following table reflects the valid settings for the device.
Paged or Global: Paged
Data Length in Bytes: 1
Data Format: Bit Field
Type: R/W
Default Value: 08h
COMMAND
OPERATION (01h)
Format
Bit Field
Bit Position
7
6
5
4
3
2
1
0
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
See Following Table
Default Value
0
0
0
0
1
0
0
0
BIT NUMBER
Bits 7:6
PURPOSE
Enable/Disable
Bits 5:4
VOUT Source
Bits 3:2
Bit 1
Bit 0
Margin Response
AVSBus Copy
Not Used
BIT VALUE
00
01
10
00
01
10
11
10
0
1
0
MEANING
Immediate off (decay)
Soft-off (Use TOFF_DELAY and TOFF_FALL)
On
VOUT_COMMAND
VOUT_MARGIN_LOW
VOUT_MARGIN_HIGH
AVSBus target rail voltage
Act on faults
VOUT_COMMAND remains unchanged
AVSBus target rail voltage changes are copied
to VOUT_COMMAND
Not used
Submit Document Feedback 24
FN8817.0
September 28, 2016