ISL68134_16 Datasheet, PDF (34/50 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68134
TON_DELAY (60h)
Definition: Sets the delay time of VOUT during enable.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: R/W
Default Value: 0014h (200µs)
Units: µs
Equation: TON_DELAY = (Direct value)*10
Range: 200µs to 655,340µs
COMMAND
TON_DELAY (60h)
Format
Direct
Bit Position
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Access
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
Two’s Complement Integer
Default Value
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
TON_RISE (61h)
Definition: Sets the rise time of VOUT during enable. Changes to this setting require a write to the APPLY_SETTINGS command before
the change will take effect. This function uses the value of VOUT to calculate rise time, so APPLY_SETTINGS must also be sent after and
change to the VOUT target for accurate rise time.
Paged or Global: Paged
Data Length in Bytes: 2
Data Format: Direct
Type: R/W
Default Value: 01F4h (500µs)
Units: µs
Equation: TON_RISE = (Direct value)
Range: 0µs to 10,000µs
COMMAND
TON_RISE (61h)
Format
Direct
Bit Position
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Access
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Function
Two’s Complement Integer
Default Value
0
0
0
0
0
0
0
1
1
1
1
1
0
1
0
0