English
Language : 

ISL68134_16 Datasheet, PDF (39/50 Pages) Intersil Corporation – Digital Dual Output, 7-Phase Configurable PWM
ISL68134
STATUS_INPUT (7Ch)
Definition: Returns a summary of input voltage faults.
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read Only
Default Value: N/A
COMMAND
STATUS_INPUT (7Ch)
Format
Bit Field
Bit Position
7
6
5
4
3
2
1
0
Access
R
R
R
R
R
R
R
R
Function
See Following Table
BIT NUMBER
7
6:5
4
3
2
1:0
MEANING
An input overvoltage fault has occurred.
Not used
An input undervoltage fault has occurred. This fault is initially masked until VIN exceeds the UV threshold
Not used
An input overcurrent fault has occurred.
Not used
STATUS_TEMPERATURE (7Dh)
Definition: Returns a summary of temperature related faults.
Paged or Global: Global
Data Length in Bytes: 1
Data Format: Bit Field
Type: Read Only
Default Value: N/A
COMMAND
STATUS_TEMPERATURE (7Dh)
Format
Bit Field
Bit Position
7
6
5
4
3
2
1
0
Access
R
R
R
R
R
R
R
R
Function
See Following Table
BIT NUMBER
7
6
5
4
3:0
An over-temperature fault has occurred.
An over-temperature warning has occurred.
Not used
An under-temperature fault has occurred.
Not used
MEANING
Submit Document Feedback 39
FN8817.0
September 28, 2016