English
Language : 

ISL12022 Datasheet, PDF (15/28 Pages) Intersil Corporation – Real Time Clock with On Chip ±5ppm Temp Compensation
ISL12022
TABLE 5. FREQUENCY SELECTION OF IRQ/FOUT PIN
FREQUENCY,
FOUT
UNITS
0
Hz
FO3
0
FO2 FO1 FO0
0
0
0
32768
Hz
0
0
0
1
4096
Hz
0
0
1
0
1024
Hz
0
0
1
1
64
Hz
0
1
0
0
32
Hz
0
1
0
1
16
Hz
0
1
1
0
8
Hz
0
1
1
1
4
Hz
1
0
0
0
2
Hz
1
0
0
1
1
Hz
1
0
1
0
1/2
Hz
1
0
1
1
1/4
Hz
1
1
0
0
1/8
Hz
1
1
0
1
1/16
Hz
1
1
1
0
1/32
Hz
1
1
1
1
POWER SUPPLY CONTROL REGISTER (PWR_VDD)
Clear Time Stamp Bit (CLRTS)
ADDR 7 6 5 4 3
2
1
0
09h CLRTS 0 0 0 0 VDDTrip2 VDDTrip1 VDDTrip0
This bit clears Time Stamp VDD to Battery (TSV2B) and Time
Stamp Battery to VDD Registers (TSB2V). The default setting
is 0 (CLRTS = 0) and the Enabled setting is 1 (CLRTS = 1).
VDD Brownout Trip Voltage BITS (VDDTrip<2:0)
These bits set the 6 trip levels for the VDD alarm, indicating
that VDD has dropped below a preset level. In this event, the
LVDD bit in the Status Register is set to “1”. See Table 6.
TABLE 6. VDD TRIP LEVELS
VDDTrip2
0
VDDTrip1
0
VDDTrip0
0
TRIP
VOLTAGE
(V)
2.295
0
0
1
2.550
0
1
0
2.805
0
1
1
3.060
1
0
0
4.250
1
0
1
4.675
Battery Voltage Trip Voltage Register (PWR_VBAT)
This register controls the trip points for the two VBAT alarms,
with levels set to approximately 85% and 75% of the nominal
battery level.
TABLE 7.
ADDR 7 6
5
4
3
2
1
0
0Ah D RESEALB VB85Tp2 VB85Tp1 VB85Tp0 VB75Tp2 VB75Tp1 VB75Tp0
RESEAL BIT (RESEALB)
This is the Reseal bit for actively disconnecting VBAT pin from
the internal circuitry. Setting this bit allows the device to
disconnect the battery and eliminate standby current drain
while the device is unused. Once VDD is powered up, this bit is
reset and the VBAT pin is then connected to the internal
circuitry.
The application for this bit involves placing the chip on a
board with a battery and testing the board. Once the board is
tested and ready to ship, it is desirable to disconnect the
battery to keep it fresh until the board or unit is placed into
final use. Setting RESEALB = “1” initiates the battery
disconnect, and after VDD power is cycled down and up
again, the RESEAL bit is cleared to “0”.
BATTERY LEVEL MONITOR TRIP BITS (VB85TP<2:0>)
Three bits select the first alarm (85% of Nominal VBAT) level for
the battery voltage monitor. There are total of 7 levels that could
be selected for the first alarm. Any of the of levels could be
selected as the first alarm with no reference as to nominal
Battery voltage level. See Table 8.
TABLE 8. VB85T ALARM LEVEL
VB85Tp2
VB85Tp1
VB85Tp0
BATTERY
ALARM TRIP
LEVEL
(V)
0
0
0
2.125
0
0
1
2.295
0
1
0
2.550
0
1
1
2.805
1
0
0
3.060
1
0
1
4.250
1
1
0
4.675
BATTERY LEVEL MONITOR TRIP BITS (VB75TP<2:0>)
Three bits select the second alarm (75% of Nominal VBAT)
level for the battery voltage monitor. There are total of 7 levels
that could be selected for the second alarm. Any of the of levels
could be selected as the second alarm with no reference as to
nominal Battery voltage level. See Table 9.
15
FN6659.2