English
Language : 

IC-MH16_15 Datasheet, PDF (8/25 Pages) IC-Haus GmbH – 12-BIT ANGULAR HALL ENCODER
iC-MH16
12-BIT ANGULAR HALL ENCODER
preliminary
Rev A1, Page 8/25
OPERATING REQUIREMENTS: Serial Interface
Operating conditions: VDD = 5 V ±10 %, Ta = -40...125 °C, IBM calibrated to 200 µA;
Logic levels referenced to VND: lo = 0...0.45 V, hi = 2.4 V...VPD
Item Symbol Parameter
No.
Conditions
SSI Protocol (ENSSI = 1)
I001 TMAS
I002 tMASh
I003 tMASl
BiSS C Protocol
Permissible Clock Period
Clock Signal hi Level Duration
Clock Signal lo Level Duration
ttos according to Table 29
I004
I005
I006
TMAS
tMASh
tMASl
Permissible Clock Period
Clock Signal hi Level Duration
Clock Signal lo Level Duration
ttos according to Table 29
Min.
Unit
Max.
250
2x ttos
ns
25
ttos
ns
25
ttos
ns
100
2x ttos
ns
25
ttos
ns
25
ttos
ns
MA
SLO
REQ
Clock 1
TMAS
tMASh tMASl
DATA
Clock 2 Clock 3
DATA
DATA
tpMA-SLO
Clock 4
DATA
Clock n
DATA
Ttos
Figure 1: Timing diagram in SSI protocol.
MA
SLO
REQ
Clock 1
TMAS
tMASh tMASl
Clock 2
ACK
Clock 3
START
Clock 4
DATA
Clock n
DATA STOP
Ttos
Figure 2: Timing diagram in BiSS C protocol.
MCD request