English
Language : 

IC-MD Datasheet, PDF (6/23 Pages) IC-Haus GmbH – ENCODER RECEIVER/COUNTER WITH SPI AND BiSS
iC-MD RS-422 QUADRATURE
preliminary
ENCODER RECEIVER/COUNTER WITH SPI AND BiSS
Rev A1, Page 6/23
OPERATING REQUIREMENTS: SPI Interface
Operating Conditions: VDD = 3 . . . 5.5 V, Tj = -40 . . . 125 °C, unless otherwise noted.
Item Symbol Parameter
No.
Conditions
SPI Interface
I001 tsCCL
Setup Time:
NCS hi → lo before SCK lo → hi
I002 tsDCL
Setup Time:
MOSI stable before SCK lo → hi
I003 thDCL
Hold Time:
MOSI stable after SCK lo → hi
I004 tCLh
Signal Duration SCK hi
I005 tCLI
Signal Duration SCK lo
I006 thCLC Hold Time: NCS lo after SCK lo → hi
I007 tCSh
Signal Duration NCS hi
I008 tpCLD
Propagation Delay:
MISO stable after SCK hi → lo
I009 tpCSD
Propagation Delay:
MISO high impedance after
NCS lo → hi
I010 f(SCK) Clock Frequency
Min.
15
20
0
25
25
25
0
Unit
Max.
ns
ns
ns
ns
ns
ns
ns
40
ns
25
ns
10
MHz
NCS
SCK
MOSI
MISO
tsCCL
MSB in
tsDCL thDCL
tristate
tCLh tpCLl
thCLC
tCSh
LSB in
NCS
SCK
MOSI
MISO
tpCLh tpCLl
thCLC
tCSh
don’t care
tpCLD
tpCLD
MSB out
tpCSD
LSB out
Figure 1: SPI write cycle (top) and read cycle (bottom)