E1962B Datasheet, PDF (8/26 Pages) Agilent(Hewlett-Packard) – cdma2000/IS-95/AMPS Mobile Test Application
CDMA Specifications
cdma2000 active cell call processing
functionality
Resident formats: IS-2000 SR1 (cdma2000)
Call processing timing tolerance: mobile transmissions typically
must be within ±6 µs of test set’s transmitted pilot channel
clock timing for proper reverse channel acquisition
Protocol stack: IS-2000 revision 0 with addendum (PREV=6)
Cell overhead channels for PREV=6:
F-Pilot: with user-settable PN offset
F-Sync: with real-time long code and system time update and
updates for user entered parameters
F-Paging: with real-time overhead messages
F-QPCH: indicates if active page will be in the next paging
channel slot
Cell parameters: NID, SID, country code (MCC), network code
(MNC), CDG esc mode, max slot cycle index, and reverse link
traffic pilot gain
Control channel parameters (PREV=6): paging rate, F-QPCH rate,
F-QPCH state, F-QPCH relative level
Paging channel data rate (PREV=6): selectable from either full or
half rate
F-QPCH data rate: selectable from either full or half rate
Access parameters (PREV=6): Nom_Pwr, Nom_Pwr_Ext,
Init_Pwr, Pwr_Step, Num_Step, Max_Req_Seq, Max_Rsp_Seq,
and Pam_Size
Call control (“one button commands”):
register
BS call originate
BS call disconnect
MS call originate (auto answer)
MS call disconnect
Registration support: user-initiated (zone-based), power up (with
on/off support), timer based (with on/off support), implicit
registration (mobile originated call), or direct user entry of
mobile IMSI
Registration reported mobile information: ESN (hex), ESN
(decimal), MCC, MNC, MSIN, slot class, slot cycle index,
protocol revision, band class, operating mode, MAX EIRP,
registration type, QPCH support, enhanced RC support,
minimum power control step size, MS called party number,
MEID supported, MEID (hex), and MEID (decimal)
Status request query control: selectable between on and off;
default of “on” causes test set to perform the status queries
during registration or mobile origination when a new ESN is
received by the test set
Max EIRP: user must enter the mobile’s maximum power in dBW
when the status request query field is set to off
IMSI support: class 0 only
Supported IMSI class 0 types: MSIN only (00), MNC + MSIN (01),
MCC + MSIN (10), or MCC + MNC + MSIN (11)
Query mobile capabilities function: uses signaling to request the
mobile’s capabilities; requested parameters include:
FCH: FCH supported, FCH 5 ms frames supported, F-FCH radio
configurations, R-FCH radio configurations
DCCH: DCCH supported, DCCH frame size, F-DCCH radio
configurations, R-DCCH radio configurations
F-SCH: F-SCH supported, number of F-SCH channels supported,
turbo encoder supported, turbo encoded rate set 1 max data
rate, turbo encoded rate set 2 max data rate, convolutional
encoder supported, convolutional encoded rate set 1 max data
rate, convolutional encoded rate set 2 max data rate
R-SCH: R-SCH supported, number of R-SCH channels
supported, turbo encoder supported, turbo encoded rate set 1
max data rate, turbo encoded rate set 2 max data rate,
convolutional encoded rate set 1 max data rate, convolutional
encoded rate set 2 max data rate
TCH/FCH service option support:
SO1
9.6 kbps voice
SO2
9.6 kbps data loopback
SO3
9.6 kbps EVRC voice
SO6
Short Message Service (Rate Set 1)
SO9
14.4 kbps data loopback
SO14
Short Message Service (Rate Set 2)
SO17
14.4 kbps voice
SO55
RC1/2/3/4/5 data loopback
SO68
9.6 kbps EVRC-B voice
SO70
9.6kbps EVRC-WB voice
SO32768 14.4 kbps voice
Loopback service option traffic data source: PRBS (CCITT 215−1
pattern)
Voice service option modes: echo with variable delay, 400 Hz sine
wave, 1 kHz sine wave, swept sine wave, multi-tone audio, real-
time vocoder, and null frames
Echo delay: selectable as short, medium, and long
F-SCH service option support:
SO32 (+F-SCH): TDSO supporting all SR1 rates up to
153.6 kbps for R-RC3 and F-RC4
SO32 (+SCH): TDSO supporting all SR1 rates up to 153.6 kbps
for F-RC3 or F-RC4 at the same time with R-RC3
IS-2000 to IS-95 handoff parameters: execute, channel, band,
protocol, and service option
IS-2000 to AMPS handoff parameters: execute, channel, SAT,
and power level
Supported TCH/FCH radio configuration combinations:
forward RC 1 + reverse RC 1
forward RC 2 + reverse RC 2
forward RC 3 + reverse RC 3
forward RC 4 + reverse RC 4
forward RC 5 + reverse RC 5
Forward TCH/FCH data rates:
RC1: random (40% duty cycle), 1.2, 2.4, 4.8, 9.6 kbps
RC2: random (40% duty cycle), 1.8, 3.6, 7.2, 14.4 kbps
RC3: random (40% duty cycle), 1.5, 2.7, 4.8, 9.6 kbps
RC4: random (40% duty cycle), 1.5, 2.7, 4.8, 9.6 kbps
RC5: random (40% duty cycle), 1.8, 3.6, 7.2, 14.4 kbps
8