Option E1962B-407 protocol logging
Functionality: start protocol logging and stop protocol logging
Protocol support: PREV=6 and PREV=7 messages; provides
correct binary output for lower PREVs but decodes using
PREV=6 messages formats
Option E1962B-409 SMS
SMS support: mobile terminated or mobile originated
SMS mobile terminated service types: point to point or broadcast
SMS mobile terminated teleservice types: wireless paging
teleservice, wireless messaging teleservice, voice mail
notification, or WAP
SMS broadcast service categories: unknown, broadcast
emergency, administrative, maintenance, general news local,
general news regional, general news national, general news
international, business and financial news local, business and
financial news regional, business and financial news national,
business and financial news international, sports news local,
sports news regional, sports news national, sports news
international, entertainment news local, entertainment news
regional, entertainment news national, entertainment news
international, local weather, area traffic reports, local flight
schedules, restaurants, lodgings, retail directory,
advertisements, stock quotes, employment opportunities,
medical, technology news, and multi-category
SMS mobile terminated originating address: maximum of 14
numeric digits
SMS mobile terminated message priority: none, normal,
interactive, urgent, and emergency
SMS mobile terminated message privacy: none, not restricted,
restricted, confidential, and secret
SMS mobile terminated message alert: default, low, medium,
high, and none
SMS mobile terminated message encoding: octet, 7-bit ASCII,
IA5, UNICODE, shift-JIS, Korean, Latin/Hebrew, Latin, and GSM
7-bit default alphabet
SMS mobile terminated message optional user data: include or
exclude
SMS mobile terminated call back number: include or exclude; set
to the originating address when included
SMS mobile terminated message entry: hex or ASCII
SMS mobile terminated message length: maximum of 255 ASCII
characters or 510 hex characters
SMS mobile terminated message repeat: 1 up to 255 repetitions
of the entered data
SMS mobile terminated messaging editing: append data,
overwrite data, insert data, clear to end, backspace, and delete
character
SMS mobile terminated message status: provides status of SMS
message transmission and reports cause codes
SMS mobile originated protocol control: enabled, disabled, not
supported, or unknown address
SMS mobile originated display: auto, ASCII, or hex
SMS mobile originated message status: message count,
teleservice type, destination address, destination address
encoding, priority, call back number, call back number
encoding, message encoding, and message length