English
Language : 

E1962B Datasheet, PDF (22/26 Pages) Agilent(Hewlett-Packard) – cdma2000/IS-95/AMPS Mobile Test Application
Fast Device Tune Measurement
E1999A-202 FDT enhanced
Single Channel GPS source
E1999A-206 Single channel GPS source
Fast Device Tune Measurement
Input frequency ranges:
411 to 420 MHz
450 to 484 MHz
824 to 934 MHz
1700 to 1980 MHz
Measurement method: allows user definition of an RF source
power output sequence simultaneously with a Tx power
measurement sequence each consisting of 10 or 20 ms
duration steps with a user-defined step size. Sequence can be
defined to repeat over a number of frequencies inside of a
single frequency band. This measurement requires a test mode
in the mobile station in order to operate. Measures the total
power in a 1.23 MHz bandwidth centered on the active reverse
channel center frequency in each step period
Measurement data capture period: 0.313 µs
Maximum input level: +37 dBm/1.23 MHz peak (5 W peak)
Measurement range: −61 to +30 dBm, usable to < −69 dBm/1.23
MHz with reduced accuracy
Measurement capture range: mobile station’s transmit power
must be within ±9 dB of the expected power per the ranging
configuration
Measurement accuracy: < ±1 dB 15 to 55 °C for the fast mode,
typically < ±0.5 dB (calibrated against average power and
within ±10 degrees of calibration temperature. Calibration must
occur between 20 to 55 °C)
Measurement resolution: 0.01 dBm/1.23 MHz
Measurement step duration (time): 10ms or 20ms
Number of frequency steps: 1 to 20
Number of amplitude steps: 1 to 20 steps at each specified
frequency
Maximum steps in a sequence: up to 20 out of the possible 40
entries in each table
MS Tx frequency step table: 1 to 40 entries, with each value in
MHz
MS Tx power step table: 1 to 40 entries, with each value in dBm
MS Rx frequency step table: 1 to 40 entries, with each value in
MHz
MS Rx power step table: 1 to 40 entries, with each value in dBm
MS Tx frequency step start index: 0 to 39
MS Tx power step start index: 0 to 39
MS Rx frequency step start index: 0 to 39
MS Rx power step start index: 0 to 39
RF generator settling time: < 5.7 ms to be within ±0.1 dB of the
final value
RF generator modulation accuracy: typically < 3.1%
RF generator level accuracy: same as listed under 1xEV-DO RF
generator specifications
Concurrency capabilities: none
Calibrate function: calibrates all measurement functions
Single Channel GPS source
Carrie: L1
Code type: Coarse/Acquisition(C/A)
Signal output: RF IN/OUT or RF OUTPUT only
Power level: -70 dBm to -125 dBm
Settable parameter:Satellite ID, data patterns and fileters
22