XR16C850 Datasheet, PDF (16/55 Pages) Exar Corporation – UART with 128-byte FIFO’s FIFO Counters and Half-duplex Control
XR16C850
SEL S3 S2 S1 A3-A9 COM Port Selected IRQ *2
0 0 0 0 3F8-3FF COM-1
0 0 0 1 2F8-2FF COM-2
0 0 1 0 3E8-3EF COM-3
0 0 1 1 2E8-2EF COM-4
IRQB (IRQ4)
IRQC (IRQ3)
IRQB (IRQ4)
IRQC (IRQ3)
0 1 0 0 3F8-3FF COM-1
0 1 0 1 2F8-2FF COM-2
0 1 1 0 3E8-3EF COM-3
0 1 1 1 2E8-2EF COM-4
IRQA (IRQn)
IRQA (IRQn)
IRQA (IRQn)
IRQA (IRQn)
0 - - - 278-27F LPT-2
N/A
0 - - - 378-37F LPT-1
N/A
Table 2. PC MODE INTERNAL ADDRESS DECODE FUNCTIONS
Note *2: All interrupt outputs are inactive (three state mode) except when the selected address range is valid.