English
Language : 

RFM95 Datasheet, PDF (98/121 Pages) List of Unclassifed Manufacturers – Low Power Long Range Transceiver Module
WIRELESS & SENSING
RFM95/96/97/98(W)
PRELIMINARY
DATASHEET
Name
(Address)
Bits
7
6
5
RegIrqFlags1
(0x3e)
4
3
2
1
0
7
6
5
4
RegIrqFlags2
(0x3f)
3
2
1
0
Variable Name
ModeReady
RxReady
TxReady
PllLock
Rssi
Timeout
PreambleDetect
SyncAddressMatch
FifoFull
FifoEmpty
FifoLevel
FifoOverrun
PacketSent
PayloadReady
CrcOk
LowBat
Mode
Default
value
FSK/OOK Description
Set when the operation mode requested in Mode, is ready
- Sleep: Entering Sleep mode
- Standby: XO is running
r
- - FS: PLL is locked
- Rx: RSSI sampling starts
- Tx: PA ramp-up completed
Cleared when changing the operating mode.
r
-
Set in Rx mode, after RSSI, AGC and AFC.
Cleared when leaving Rx.
r
-
Set in Tx mode, after PA ramp-up.
Cleared when leaving Tx.
r
-
Set (in FS, Rx or Tx) when the PLL is locked.
Cleared when it is not.
rwc
-
Set in Rx when the RssiValue exceeds RssiThreshold.
Cleared when leaving Rx or setting this bit to 1.
r
-
Set when a timeout occurs
Cleared when leaving Rx or FIFO is emptied.
rwc
-
Set when the Preamble Detector has found valid Preamble.
bit clear when set to 1
Set when Sync and Address (if enabled) are detected.
rwc - Cleared when leaving Rx or FIFO is emptied.
This bit is read only in Packet mode, rwc in Continuous mode
r
- Set when FIFO is full (i.e. contains 66 bytes), else cleared.
r
-
Set when FIFO is empty, and cleared when there is at least 1 byte
in the FIFO.
r
-
Set when the number of bytes in the FIFO strictly exceeds
FifoThreshold, else cleared.
Set when FIFO overrun occurs. (except in Sleep mode)
rwc
-
Flag(s) and FIFO are cleared when this bit is set. The FIFO then
becomes immediately available for the next transmission /
reception.
r
-
Set in Tx when the complete packet has been sent.
Cleared when exiting Tx
Set in Rx when the payload is ready (i.e. last byte received and
r
- CRC, if enabled and CrcAutoClearOff is cleared, is Ok). Cleared
when FIFO is empty.
r
-
Set in Rx when the CRC of the payload is Ok. Cleared when FIFO
is empty.
rwc
-
Set when the battery voltage drops below the Low Battery
threshold. Cleared only when set to 1 by the user.
IO control registers
Page 98
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http:/ / www.hoperf.com