English
Language : 

RFM95 Datasheet, PDF (12/121 Pages) List of Unclassifed Manufacturers – Low Power Long Range Transceiver Module
WIRELESS & SENSING
RFM95/96/97/98(W)
PRELIMINARY
DATASHEET
2. Electrical Characteristics
2.1. ESD Notice
The RFM95/96/97/98(W) is a high performance radio frequency device. It satisfies:
Š Class 2 of the JEDEC standard JESD22-A114-B (Human Body Model) on all pins.
Š Class III of the JEDEC standard JESD22-C101C (Charged Device Model) on all pins
It should thus be handled with all the necessary ESD precautions to avoid any permanent damage.
2.2. Absolute Maximum Ratings
Stresses above the values listed below may cause permanent device failure. Exposure to absolute maximum ratings for
extended periods may affect device reliability.
Table 49 Absolute Maximum Ratings
Symbol
VDDmr
Tmr
Tj
Pmr
Supply Voltage
Temperature
Junction temperature
RF Input Level
Description
Note Specific ratings apply to +20 dBm operation (see Section 5.4.3).
2.3. Operating Range
Table 50 Operating Range
Min
Max
Unit
-0.5
3.9
V
-55
+115
°C
-
+125
°C
-
+10
dBm
Symbol
Description
Min
VDDop
Supply voltage
1.8
Top
Operational temperature range
-20
Clop
Load capacitance on digital ports
-
ML
RF Input Level
-
Note A specific supply voltage range applies to +20 dBm operation (see Section 5.4.3).
Max
Unit
3.7
V
+70
°C
25
pF
+10
dBm
Page 12