Set RF64 in OOK Rx mode Adjust Bit
Rate, Channel filter BW Default
RXParam_OOK_thresh setting No
input signal
Continuous Mode
Increment
MCParam_OOK_floor_thres
Monitor DATA pin (pin 20)
Glitch activity
on DATA ?
RF64
Optimization complete
Figure 23: Floor Threshold Optimization
The new floor threshold value found during this test should be the value used for OOK reception with those receiver
settings.
Note that if the output signal on DATA is logic “1”, the value of MCParam_OOK_floor_thres is below the noise floor
of the receiver chain. Conversely, if the output signal on DATA is logic “1”, the value of MAParam_floor_thres is
several dB above the noise floor.
3.4.10.2. Optimizing OOK Demodulator Response for Fast Fading Signals
A sudden drop in signal strength can cause the bit error rate to increase. For applications where the expected
signal drop can be estimated the following OOK demodulator parameters RXParam_OOK_thresh_step and
RXParam_OOK_thresh_dec_period can be optimized as described below for a given number of threshold
decrements per bit RXParam_OOK_thresh_dec_period: