English
Language : 

AP9319 Datasheet, PDF (28/30 Pages) List of Unclassifed Manufacturers – Environmental Monitoring Unit
Specifications
Electrical
Input voltage, nominal
24 VDC
Maximum total current draw 380 mA @ 24 VDC (with standard probes attached)
Temperature accuracy
±2º C (±3º F ), from 0 to 40º C (32 to 104º F)
Humidity accuracy
±8 % RH, 10 to 90% RH, at 25º C (77º F)
±8 % RH, 30 to 80% RH, from 15 to 30 º C (59 to 95º F)
Probe zone input
response time
200 mS
A-Link power output
24 VDC nominal, 250 mA maximum, ground referenced
Physical
Size (H × W× D)
1.72 × 7.90 × 4.60 in (4.37 × 20.10 × 11.68 cm)
Weight
2 lb (0.91 kg)
Shipping weight
4.25 lb (1.93 kg)
Environmental
Elevation (above MSL)
Operating
Storage
Temperature
Operating
Storage
0 to 10 000 ft (0 to 3000 m)
0 to 50 000 ft (0 to 15 000 m)
0 to 40° C (32 to 104° F)
0 to 45° C (32 to 113° F)
Operating humidity
0 to 95%, non-condensing
Probe operating temperature 0 to 60º C (32 to 140º F)
Compliance
Approvals
FCC Class A, VCCI Class A, ICES-003 Class A,
EN 55022 Class A, AS/NZS 3548
Electromagnetic immunity EN 55024
24
Environmental Monitoring Unit — Installation and Quick Start