English
Language : 

SLFLD25-128J Datasheet, PDF (18/21 Pages) List of Unclassifed Manufacturers – 128 MB to 8 GB 2.5-Inch IDE Flash Drives
SLFLD25-xxxJ(I)
IDE FLASH DRIVE
Identify Drive Information (continued)
(Serial Number, Firmware Revision, and Model Number)
Serial Number Format (typical): Words 10-19
SimpleTech Proprietary Yr Day Hr Min Sec
STI_J13C0
04 224 09 27 50
Firmware Revision: Words 23-26
mm/dd/yy
Model Number: Words 27-46
STI Flash X.Y.Z
Idle
(code: E3h or 97h)
This command causes the drive to set BSY, enter the Idle
mode, clear BSY, and generate an interrupt. If the sector
count is non-zero, automatic power down mode is enabled. If
the sector count is zero, the automatic power down mode is
disabled.
Idle Immediate
(code: E1h or 95h)
This command causes the drive to set BSY, enter the Idle
(Read) mode, clear BSY, and generate an interrupt.
Initialize Drive Parameters
(code: 91h)
This command enables the host to set the number of sectors
per track and the number of heads per cylinder.
Read Buffer
(code: E4h)
This command enables the host to read the current contents
of the drive’s sector buffer.
Read Multiple
(code: C4h)
This command performs similarly to the Read Sectors
command. Interrupts are not generated on each sector, but on
the transfer of a block which contains the number of sectors
defined by a Set Multiple command.
Read Long Sector
(code: 22h or 23h)
This command performs similarly to the Read Sector(s)
command except that it returns 516 bytes of data instead of
512 bytes.
Read Sector(s)
(code: 20h or 21h)
This command reads from 1 to 256 sectors as specified in the
Sector Count register. A sector count of 0 requests 256 sectors.
The transfer begins at the sector specified in the Sector
Number register.
Read Verify Sector(s)
(code: 40h or 41h)
This command verifies one or more sectors on the drive by
transferring data from the flash media to the data buffer in
the drive and verifying that the ECC is correct. This
commandis identical to the Read Sectors command, except
that DRQ is never set and no data is transferred to the host.
This
Recalibrate
(code: 1Xh)
The ComapactFlash performs only the interface timing and
register operations. When this command is issued, the
ComapactFlash sets BSY and waits for an appropriate length
of time after which it clears BSY and issues an interrupt.
When this command ends normally, the ComapactFlash is
initialized
Request Sense
(code: 03h)
This command requests an extended error code after a
command ends with an error. Refer to table below.
Code
00H
01H
09H
20H
21H
2FH
35H, 36H
11H
18H
05H, 30H-34H, 37H, 3EH
10H, 14H
3AH
1FH
0CH, 38H, 3BH, 3CH, 3FH
03H
22H
Description
No error detected
Self test OK (No error)
Miscellaneous Error - N/A
Invalid Command
Invalid Address (requested
Head or Sector invalid)
Address Overflow (address too
large)
Supply or generate Voltage Out
of Tolerance
Uncorrectable ECC Error
Correctable ECC Error - N/A
Self Test Diagnostic Failed
ID Not Found - N/A
Spare Sectors Exhausted
Data Transfer Error / Aborted
Command
Corrupted Media Format - N/A
Write / Erase Failed - N/A
Power Level 1 Disabled
Document Part Number 61000-02817-109 March 2005 Page 18