English
Language : 

SLFLD25-128J Datasheet, PDF (16/21 Pages) List of Unclassifed Manufacturers – 128 MB to 8 GB 2.5-Inch IDE Flash Drives
SLFLD25-xxxJ(I)
IDE FLASH DRIVE
ATA COMMAND SPECIFICATIONS
This table with the following paragraphs summarizes the
ATA command set.
No. Command set
Code
FR SC SN CY DR HD LBA
1 Check Power Mode
E5h or 98h — Y — — Y — —
2 Execute Drive Diagnostic 90h
— — — — Y** — —
3 Erase Sector(s)
C0h
—Y Y YY Y Y
4 Format Track
50h
—Y—YY Y Y
5 Identify Drive
ECh
Y ———Y — —
6 Idle
E3h or 97h — Y — — Y — —
7 Idle Immediate
E1h or 95h — — — — Y — —
8 Initialize Drive Parameters 91h
— Y ——Y Y —
9 Read Buffer
E4h
————Y — —
10 Read Multiple
C4h
—Y Y YY Y Y
11 Read Long Sector
22h or 23h* — — Y Y Y Y Y
12 Read Sector(s)
20h or 21h* — Y Y Y Y Y Y
13 Read Verify Sector(s)
40h or 41h* — Y Y Y Y Y Y
14 Recalibrate
1Xh
————Y — —
15 Request Sense
03h
————Y — —
16 Seek
7Xh
—— Y YY Y Y
17 Set Features
EFh
—Y Y YY Y —
18 Set Multiple Mode
C6h
— Y ——Y — —
19 Set Sleep Mode
E6h or 99h — — — — Y — —
20 Stand By
E2h or 96h — Y — — Y — —
21 Stand By Immediate
E0h or 94h — — — — Y — —
22 Translate Sector
87h
—Y Y YY Y Y
23 Wear Level
F5h
————Y Y —
24 Write Buffer
E8h
————Y — —
25 Write Long Sector
32h or 33h* — Y Y Y Y Y Y
26 Write Multiple
C5h
—Y Y YY Y Y
27 Write Multiple w/o Erase CDh
—Y Y YY Y Y
28 Write Sector(s)
30h or 31h* — Y Y Y Y Y Y
29 Write Sector(s) w/o Erase 38h
—Y Y YY Y Y
30 Write Verify
3Ch
—Y Y YY Y Y
FR=Features Register,
SC=Sector Count Register (00h
to FFh), SN=Sector Number
Register (01h to 20h),
CY=Cylinder Registers,
DR=Drive bit of Drive/Head
Register, HD=Head no. (0 to
3) of Drive/Head Register,
LBA=Logical Block Address
Mode Supported.
Y—Set up.
“—” —Not set up.
* First command
code=with retry,
Second command
code=without retry.
** Address to drive 0.
Both drives execute
command
Document Part Number 61000-02817-109 March 2005 Page 16