English
Language : 

SLFLD25-128J Datasheet, PDF (17/21 Pages) List of Unclassifed Manufacturers – 128 MB to 8 GB 2.5-Inch IDE Flash Drives
SLFLD25-xxxJ(I)
IDE FLASH DRIVE
Check Power Mode
(code: E5h or 98h)
Format Track
(code: 50h)
This command checks the power mode.
This command writes the desired head and cylinder of the
Execute Drive Diagnostic
(code: 90h)
This command performs the internal diagnostic tests
implemented by the drive. See ERROR register for dianostic
codes.
selected drive with a vender unique data pattern (typically
00h or FFh). This drive accepts a sector buffer of data from
the host to follow the command with the same protocol as
the Write Sector Command although the information in the
buffer is not used.
Identify Drive
Erase Sector(s)
(code: ECh)
(code: C0h)
This command enables the host to receive parameter
information from the drive. (See table below.)
This command is used to pre-erase and condition data
sectors in advance.
Identify Drive Information (Typical)
Word
Data Total
Description
Address
Bytes
0
044AH
2
General configuration bit-significant information—value fixed by CFA
1
XXXXH
2
Default number of cylinders
2
0000H
2
Reserved
3
00XXH
2
Default number of heads
4
XXXXH
2
Do not use this word. Before retirement, was number of unformatted bytes per track
5
XXXXH
2
Do not use this word. Before retirement, was number of unformatted bytes per sector
6
XXXXH
2
Default number of sectors per track
7-8
XXXXH
4
Number of sectors per card (word7=MSW, word 8 = LSW)
9
0000H
2
Reserved
10-19
XXXXH
2 0 Serial Number (see table next page for definition)
20
XXXXH
2
Do not use this word. Before retirement, was buffer type
21
XXXXH
2
Do not use this word. Before retirement, was buffer size in 512 byte increments
22
0004H
2
# of ECC bytes passed on Read/Write Long commands
23-46
XXXXH
4 8 Firmware revision and model number in ASCII (see table next page for definition)
47
0001H
2
Maximum of 1 sector on Read/Write Multiple command
48
0000H
2
Double Word not supported
49
0200H
2
DMA not supported, LBA supported
50
0000H
2
Reserved
51
0200H
2
PIO data transfer cycle timing mode
52
0000H
2
Single word DMA data transfer cycle timing mode (not supported)
53
0003h
2
Words 54 - 58 and 64 - 70 are valid
54
XXXXH
2
Number of Current Cylinders
55
XXXXH
2
Number of Current Heads
56
XXXXH
2
Number of Current Sectors Per Track
57
XXXXH
2
LSW of the Current Capacity in Sectors
58
XXXXH
2
MSW of the Current Capacity in Sectors
59
010XH
2
Current Setting for Block Count=1 for R/W Multiple commands
60-61
XXXXH
4
Total number of sectors addressable in LBA Mode
62
0000H
2
Single word DMA transfer not supported
63
0000H
2
Multiword DMA modes not supported
64
0003H
2
Advanced PIO modes supported (modes 3 and 4)
65
0000H
2
Minimum multiword DMA transfer cycle time per word (ns)
66
0000H
2
Recommended multiword DMA transfer cycle time per word (ns)
67
0078H
2
Minimum PIO transfer without flow control
68
0078H
2
Minimum PIO transfer with IORDY flow control
69-255 0000H
388 Reserved
XXXXH: These values are dependent upon the the specific card.
Document Part Number 61000-02817-109 March 2005 Page 17