4.3 – 4.4
4.0 Commands
4.3 SET PAGE ADDRESS
This command is used to specify a page address equivalent to a row address for MPU access to
the display data RAM. A required bit of the display data RAM can be accessed by specifying its
page address and column address. Changing the page address causes no change in display.
R/W
A0 RD WR D7
D0
0 1 0 1 0 1 1 1 0 A1 A0
A1
A0
0
0
0
1
1
0
1
1
Page
0
1
2
3
4.4 COLUMN ADDRESS
This command specifies a display data RAM column address. The column address is incremented
by 1 each time the MPU accesses from the set address to the display data RAM. Thus, it is pos-
sible for the MPU to gain continuous access to only the data. This incrementing stops with address
80; the page address is not continuously changed.
R/W
A0 RD WR D7
D0
0 1 0 0 A6 A5 A4 A3 A2 A1 A0
A6 A5 A4 A3 A2 A1 A0 Column address
0000000
0
0000001
1
—
—
—
—
1001111
79