Application Notes continued
Table 5
Register
0x25
0x26
0x27
0x11
Hold Over History access and Control Registers
Register Name
History_Policy
History_Cmd
Holdover_Time
DPLL_Status
Description
Sets policy for Hold Over history accumulation: âRebuildâ or âContinueâ
Save, restore, and flush commands for Hold Over history
Indicates the time since entering the Hold Over state
Bits 3 and 4: Hold Over Availableâ and âHold Over Build Completeâ
Figure 9
Hold Over History and Status States
Reference Switch
Flush
Reference Switch
Acquire Reference
Hold Control = 0
Hold Available = 0
Reference Lock
Flush
Build History
Hold Control = 0
Hold Available = 0
History Build Complete
Flush
Reference Lock
(with "Continue" set)
Reference Switch
Reference Switch
History Restored from backup,
re-start the building procedure.
Locked, History
Complete
Hold Control =1
Hold Available = 1
Reference Switch
Acquire Reference
Hold Control = 0
Hold Available = 1
Reference Lock
(with "Rebuild" set)
Build History
Hold Control = 0
Hold Available = 1
History Build
Complete,
Replace Active
Hold Over History
SM3G5 Data Sheet #: TM083 Page 27 of 36 Rev: 05 Date: 01/26/11
© Copyright 2011 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
|
▷ |