English
Language : 

CDB4923 Datasheet, PDF (9/50 Pages) Cirrus Logic – Evaluation Board
CDB4923 CDB49300
Digital Input
Digital Output
CS8404A CS8404A CS8404A
RESET
Control
Interface
CRD4923-MEM
CDB49300-MEM
PLD
OSC
+2.5V
+3.3V
CS492x
CS493xx
CS4340
CS4340
CS4340
CS5334
Analog
Output
Stereo
Analog In
Patch Area
Figure 1. External Memory Example
input ports of the DSP. These configuration allows
the user to drive signals on stake headers J11 and
J12 in order to operate the DSP as if it were part of
an embedded system. The user is responsible for
providing the appropriate clocking signals, control
signals, and data signals to the DSP in full external
mode, but the user only provides control signals in
exernal control mode.
In the external modes the audio output of the DSP
still drives the on-board DACs and digital transmit-
ters thus allowing the user to access the audio on
the analog and digital output connectors provided
by the CDB4923/300. The stake headers J11 and
J12 can be found in Figure 4.
All on-board clocks and data lines are routed
through the PLD (U11) in order to provide maxi-
mum flexibility in the evaluation of different sys-
tem configurations. The PLD will perform all +5 V
to +3.3 V/+2.5 V conversions between the DSP
and the +5 V parts with which it interacts by con-
figuring the I/O power jumper (J63). The system
can also be configured in an external interface de-
scribed above. The external modes are detailed in
Data Selection. All PLD modes are selected using
DIP switch S3. The PLD (U11) and switch S3 are
shown in Figure 7.
A specialized IC (U12), the MAX708, has been in-
cluded on the CDB4923/300 in order to generate a
system reset at power-up, when the digital power
begins to fail, and when the system reset button
(SW1) is depressed. This chip helps to insure con-
sistent operation on the board by providing a
200 ms reset pulse whenever activated.
5. DATA SELECTION
Data selection on the CDB4923/300 refers to the
routing of audio data, audio clocks, control data,
and control clocks. Because the PLD plays such a
crucial role in determining the routing and control
scheme, each data selection mode is also referred to
as a ‘PLD mode.’ It is important to note that Table
2, the PLD Mode table, is based directly upon the
version of the control PLD (U11) used on each par-
ticular board. Each PLD has a specific revision
code printed on its label. If your PLD version dif-
fers from the one described in this document, con-
tact the factory to determine which feature set is
provided with your board.
DS262DB2