EP3C5_1 Datasheet, PDF (8/34 Pages) Altera Corporation – Cyclone III Device Data Sheet | |||
|
◁ |
1â8
Chapter 1: Cyclone III Device Data Sheet
Electrical Characteristics
Table 1â7 lists the OCT calibration accuracy at device power-up.
Table 1â7. Cyclone III Devices Series OCT with Calibration at Device Power-Up Specifications
Description
Series OCT with
calibration at device
power-up
Calibration Accuracy
VCCIO (V)
Commercial Max
Industrial and Automotive
Max
Unit
3.0
±10
±10
%
2.5
±10
±10
%
1.8
±10
±10
%
1.5
±10
±10
%
1.2
±10
±10
%
The OCT resistance may vary with the variation of temperature and voltage after
calibration at device power-up. Use Table 1â8 and Equation 1â1 to determine the final
OCT resistance considering the variations after calibration at device power-up.
Table 1â8 lists the change percentage of the OCT resistance with voltage and
temperature.
Table 1â8. Cyclone III Devices OCT Variation After Calibration at Device Power-Up
Nominal Voltage
3.0
2.5
1.8
1.5
1.2
dR/dT (%/°C)
0.262
0.234
0.219
0.199
0.161
dR/dV (%/mV)
â0.026
â0.039
â0.086
â0.136
â0.288
Equation 1â1. (Note 1), (2), (3), (4), (5), (6)
ÎRV = (V2 â V1) Ã 1000 Ã dR/dV âââââ (7)
ÎRT = (T2 â T1) Ã dR/dT âââââ (8)
For ÎRx < 0; MFx = 1/ (|ÎRx|/100 + 1) âââââ (9)
For ÎRx > 0; MFx = ÎRx/100 + 1 âââââ (10)
MF = MFV Ã MFT âââââ (11)
Rfinal = Rinitial à MF âââââ (12)
Notes to Equation 1â1:
(1) T2 is the final temperature.
(2) T1 is the initial temperature.
(3) MF is multiplication factor.
(4) Rfinal is final resistance.
(5) Rinitial is initial resistance.
(6) Subscript à refers to both V and T.
(7) ÎRV is variation of resistance with voltage.
(8) ÎRT is variation of resistance with temperature.
(9) dR/dT is the change percentage of resistance with temperature after calibration at device power-up.
(10) dR/dV is the change percentage of resistance with voltage after calibration at device power-up.
(11) V2 is final voltage.
(12) V1 is the initial voltage.
Cyclone III Device Handbook, Volume 2
© January 2010 Altera Corporation
|
▷ |