EP3C5_1 Datasheet, PDF (4/34 Pages) Altera Corporation – Cyclone III Device Data Sheet | |||
|
◁ |
1â4
Chapter 1: Cyclone III Device Data Sheet
Electrical Characteristics
Figure 1â1 shows the methodology to determine the overshoot duration.
Figure 1â1. Cyclone III Devices Overshoot Duration
4.2 V
4.1 V
3.3 V
ÎT
T
Recommended Operating Conditions
This section lists the functional operation limits for AC and DC parameters for
Cyclone III devices. The steady-state voltage and current values expected from
Cyclone III devices are provided in Table 1â3. All supplies must be strictly monotonic
without plateaus.
Table 1â3. Cyclone III Devices Recommended Operating Conditions (Note 1), (2) (Part 1 of 2)
Symbol
Parameter
Conditions
Min Typ Max Unit
VCCINT (3)
Supply voltage for internal logic
â
1.15 1.2 1.25
V
Supply voltage for output buffers, 3.3-V
operation
â
3.135 3.3 3.465 V
Supply voltage for output buffers, 3.0-V
operation
â
2.85
3
3.15
V
Supply voltage for output buffers, 2.5-V
operation
â
2.375 2.5 2.625 V
VCCIO (3), (4)
Supply voltage for output buffers, 1.8-V
operation
â
1.71 1.8 1.89
V
Supply voltage for output buffers, 1.5-V
operation
â
1.425 1.5 1.575 V
Supply voltage for output buffers, 1.2-V
operation
â
1.14 1.2 1.26
V
VCCA (3)
Supply (analog) voltage for PLL
regulator
â
2.375 2.5 2.625 V
V (3) CCD_PLL
VI
VO
Supply (digital) voltage for PLL
Input voltage
Output voltage
â
1.15 1.2 1.25
V
â
â0.5 â
3.6
V
â
0
â
VCC IO
V
Cyclone III Device Handbook, Volume 2