1–2
Chapter 1: Cyclone III Device Data Sheet
Electrical Characteristics
Table 1–1. Cyclone III Devices Absolute Maximum Ratings (Note 1) (Part 2 of 2)
Symbol
Parameter
Min
Max
Unit
IOUT
DC output current, per pin
–25
40
mA
VE S D H BM
Electrostatic discharge voltage using the human
body model
—
±2000
V
VE S D CD M
Electrostatic discharge voltage using the
charged device model
—
±500
V
TS T G
Storage temperature
–65
150
°C
TJ
Operating junction temperature
–40
125
°C
Note to Table 1–1:
(1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the
power supply.
Maximum Allowed Overshoot or Undershoot Voltage
During transitions, input signals may overshoot to the voltage listed in Table 1–2 and
undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods
shorter than 20 ns. Table 1–2 lists the maximum allowed input overshoot voltage and
the duration of the overshoot voltage as a percentage over the lifetime of the device.
The maximum allowed overshoot duration is specified as percentage of high-time
over the lifetime of the device.
1 A DC signal is equivalent to 100% duty cycle. For example, a signal that overshoots to
4.2 V can only be at 4.2 V for 10.74% over the lifetime of the device; for device lifetime
of 10 years, this amounts to 10.74/10ths of a year.