EP2AGX190FF35C4N Datasheet, PDF (20/90 Pages) Altera Corporation – Volume 3: Device Datasheet and Addendum | |||
|
◁ |
1â12
Chapter 1: Device Datasheet for Arria II Devices
Electrical Characteristics
Use the following with Equation 1â1:
â RSCAL is the OCT resistance value at power up.
â ïT is the variation of temperature with respect to the temperature at power up.
â ïV is the variation of voltage with respect to the VCCIO at power up.
â dR/dT is the percentage change of RSCAL with temperature.
â dR/dV is the percentage change of RSCAL with voltage.
Table 1â14 lists the OCT variation with temperature and voltage after power-up
calibration for Arria II GX devices.
Table 1â14. OCT Variation after Power-up Calibration for Arria II GX Devices
Nominal Voltage VCCIO (V)
3.0
2.5
1.8
1.5
1.2
dR/dT (%/°C)
0.262
0.234
0.219
0.199
0.161
dR/dV (%/mV)
0.035
0.039
0.086
0.136
0.288
Table 1â15 lists the OCT variation with temperature and voltage after power-up
calibration for Arria II GZ devices.
Table 1â15. OCT Variation after Power-Up Calibration for Arria II GZ Devices (Note 1)
Nominal Voltage, VCCIO (V)
3.0
dR/dT (%/°C)
0.189
2.5
0.208
1.8
0.266
1.5
0.273
1.2
0.317
Note to Table 1â15:
(1) Valid for VCCIO range of ±5% and temperature range of 0° to 85°C.
dR/dV (%/mV)
0.0297
0.0344
0.0499
0.0744
0.1241
Pin Capacitance
Table 1â16 lists the pin capacitance for Arria II GX devices.
Table 1â16. Pin Capacitance for Arria II GX Devices
Symbol
Description
Typical
Unit
CIO
Input capacitance on I/O pins, dual-purpose pins (differential I/O, clock,
Rup, Rdn), and dedicated clock input pins
7
pF
Arria II Device Handbook Volume 3: Device Datasheet and Addendum
July 2012 Altera Corporation
|
▷ |