English
Language : 

EP2AGX190FF35C4N Datasheet, PDF (13/90 Pages) Altera Corporation – Volume 3: Device Datasheet and Addendum
Chapter 1: Device Datasheet for Arria II Devices
1–5
Electrical Characteristics
Recommended Operating Conditions
This section lists the functional operation limits for AC and DC parameters for
Arria II GX and GZ devices. All supplies are required to monotonically reach their
full-rail values without plateaus within tRAMP .
Table 1–5 lists the recommended operating conditions for Arria II GX devices.
Table 1–5. Recommended Operating Conditions for Arria II GX Devices (Note 1) (Part 1 of 2)
Symbol
Description
Condition Minimum Typical Maximum Unit
Supplies power to the core, periphery, I/O
VCC
registers, PCIe HIP block, and transceiver
—
PCS
0.87
0.90
0.93
V
VCCCB
Supplies power to the configuration RAM
bits
—
1.425
1.50
1.575
V
VCCBAT
(2)
Battery back-up power supply for design
security volatile key registers
—
1.2
—
3.3
V
VCCPD
(3)
Supplies power to the I/O pre-drivers,
differential input buffers, and MSEL
circuitry
—
3.135
3.3
3.465
V
—
2.85
3.0
3.15
V
—
2.375
2.5
2.625
V
—
3.135
3.3
3.465
V
—
2.85
3.0
3.15
V
VCCIO
Supplies power to the I/O banks (4)
—
2.375
2.5
2.625
V
—
1.71
1.8
1.89
V
—
1.425
1.5
1.575
V
—
1.14
1.2
1.26
V
VCCD_PLL
Supplies power to the digital portions of the
PLL
—
0.87
0.90
0.93
V
Supplies power to the analog portions of
VCCA_PLL the PLL and device-wide power
management circuitry
—
2.375
2.5
2.625
V
VI
DC Input voltage
VO
Output voltage
VCCA
Supplies power to the transceiver PMA
regulator
—
–0.5
—
3.6
V
—
0
—
VCCIO
V
—
2.375
2.5
2.625
V
VCCL_GXB
Supplies power to the transceiver PMA TX,
PMA RX, and clocking
—
1.045
1.1
1.155
V
VCCH_GXB
Supplies power to the transceiver PMA
output (TX) buffer
—
1.425
1.5
1.575
V
TJ
Operating junction temperature
Commercial
0
—
85
°C
Industrial
–40
—
100
°C
July 2012 Altera Corporation
Arria II Device Handbook Volume 3: Device Datasheet and Addendum