English
Language : 

X9470 Datasheet, PDF (8/25 Pages) Xicor Inc. – RF Power Amplifier (PA) Bias Controller
Preliminary Information
X9470
AC SPECIFICATIONS
Symbol
fSCL
tIN(10)
tAA(10)
tBUF(10)
tLOW
tHIGH
tSU:STA
tHD:STA
tSU:DAT
tHD:DAT
tSU:STO
tDH(10)
tR(10)
tF(10)
Cb(10)
Parameter
SCL Clock Frequency
Pulse width Suppression Time at inputs
SCL LOW to SDA Data Out Valid
Time the bus must be free before a new transmission can start
Clock LOW Time
Clock HIGH Time
Start Condition Setup Time
Start Condition Hold Time
Data In Setup Time
Data In Hold Time
Stop Condition Setup Time
Data Output Hold Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Capacitive load for each bus line
Note: (12) Cb = total capacitance of one bus line in pF.
TIMING DIAGRAMS
Bus Timing
Min.
0
50
0.1
1.3
1.3
0.6
0.6
0.6
200
200
0.6
50
20 +.1Cb(12)
20 +.1Cb(12)
Max.
400
0.9
300
300
400
Unit
kHz
ns
µs
µs
µs
µs
µs
µs
ns
ns
µs
ns
ns
ns
pF
SCL
tSU:ST
SDA IN
SDA OUT
tF
tHIGH
tSU:DAT
tHD:STA
tLOW
tHD:DAT
tR
tAA tDH
tSU:STO
tBUF
REV 11.16 3/20/03
www.xicor.com
8 of 25