English
Language : 

X9470 Datasheet, PDF (17/25 Pages) Xicor Inc. – RF Power Amplifier (PA) Bias Controller
Preliminary Information
X9470
State 3: PA Standby Mode, DC Bias Adjustment
[Compensation for VGS Drift and Temperature
Variation]
When the Power Amplifier is in Standby Mode the
X9470 allows for dynamic adjustment of the DC bias-
ing point to take into account both VGS drift and tem-
perature variation. Dynamic biasing is achieved with
the X9470 by using the CS, and SCL pins. For exam-
ple, the SCL pin can be a steady clock and the CS pin
can be used as a control signal to enable/disable the
Bias Adjustment Block.
Figure 6 illustrates how the X9470 can be used for
dynamic biasing. Upon the presence of an RF signal,
the CS pin is pulled LOW. This will prevent the X9470
from changing the VBIAS voltage during IDQ peak cur-
rents. Once the RF signal is no longer present, the CS
pin can be enabled (closed loop), SDA high and the
X9470 Bias Adjustment Circuit moves the VBIAS volt-
age (the gate voltage of the FET) to meet the average
IDQ bias point for optimum amplifier performance.
State 4: Power Off Mode
During power saving or power-off modes the X9470
can be shut down via the SHDN pin. This pin pulls the
output of the VBIAS pin LOW.
REV 11.16 3/20/03
www.xicor.com