English
Language : 

W83697HG Datasheet, PDF (90/109 Pages) Winbond – WINBOND LPC I/O
W83697HF/ HG
7.14 Logical Device B (Hardware Monitor)
CR30 (Default 0x00)
Bit 7 - 1: Reserved.
Bit 0: = 1 Activates the logical device.
= 0 Logical device is inactive.
CR60, CR 61 (Default 0x00, 0x00)
These two registers select Hardware Monitor base address [0x100:0xFFF] on 8-byte boundary.
CR70 (Default 0x00)
Bit 7 - 4: Reserved.
Bit 3 - 0: These bits select IRQ resource for Hardware Monitor.
- 87 -
Publication Release Date: May 30, 2005
Revision A1