English
Language : 

W83697HG Datasheet, PDF (38/109 Pages) Winbond – WINBOND LPC I/O
W83697HF/ HG
Data Register (Port x6h)
Data Port:
Power on Default Value
Attribute:
Size:
Port x6h
00h
Read/write
8 bits
7 6 54321 0
Data
Bit 7-0: Data to be read from or to be written to RAM and Register.
Configuration Register  Index 40h
Register Location:
40h
Power on Default Value
01h
Attribute:
Read/write
Size:
8 bits
7 6 54321 0
START
SMI#Enable
RESERVED
INT_Clear
RESERVED
RESERVED
RESERVED
INITIALIZATION
Bit 7: A one restores power on default value to all registers except the Serial Bus Address register.
This bit clears itself since the power on default is zero.
Bit 6: Reserced
Bit 5: Reserved
Bit 4: Reserved
Bit 3: A one disables the SMI# output without affecting the contents of Interrupt Status Registers. The
device will stop monitoring. It will resume upon clearing of this bit.
Bit 2: Reserved
Bit 1: A one enables the SMI# Interrupt output.
Bit 0: A one enables startup of monitoring operations, a zero puts the part in standby mode.
Note: The outputs of Interrupt pins will not be cleared if the user writes a zero to this location after an
interrupt has occurred unlike "INT_Clear'' bit.
- 35 -
Publication Release Date: May 30, 2005
Revision A1