English
Language : 

W83697HG Datasheet, PDF (79/109 Pages) Winbond – WINBOND LPC I/O
W83697HF/ HG
IR MODE IR FUNCTION
IRTX
00X
Disable
tri-state
010*
IrDA
Active pulse 1.6 µS
011*
IrDA
Active pulse 3/16 bit time
100
ASK-IR
Inverting IRTX/SOUTB pin
101
ASK-IR
Inverting IRTX/SOUTB & 500
KHZ clock
110
ASK-IR
Inverting IRTX/SOUTB
111*
ASK-IR
Inverting IRTX/SOUTB & 500
KHZ clock
Note: The notation is normal mode in the IR function.
IRRX
high
Demodulation into SINB/IRRX
Demodulation into SINB/IRRX
routed to SINB/IRRX
routed to SINB/IRRX
Demodulation into SINB/IRRX
Demodulation into SINB/IRRX
Bit 2: HDUPLX. IR half/full duplex function select.
= 0 The IR function is Full Duplex.
= 1 The IR function is Half Duplex.
Bit 1: TX2INV.
= 0 the SOUTB pin of UART B function or IRTX pin of IR function in normal condition.
= 1 inverse the SOUTB pin of UART B function or IRTX pin of IR function.
Bit 0: RX2INV.
= 0 the SINB pin of UART B function or IRRX pin of IR function in normal condition.
= 1 inverse the SINB pin of UART B function or IRRX pin of IR function
7.9 Logical Device 6 (CIR)
CR30 (Default 0x00)
Bit 7 - 1: Reserved.
Bit 0: = 1 Activates the logical device.
= 0 Logical device is inactive.
CR60, CR 61 (Default 0x00, 0x00)
These two registers select CIR I/O base address [0x100:0xFF8] on 8 byte boundary.
CR70 (Default 0x00)
Bit 7 - 4: Reserved.
Bit [3:0]: These bits select IRQ resource for CIR.
- 76 -