W83697HF/ HG
Reserved Register -- Index 5Ch (Bank 4)
Reserved Register -- Index 5Dh (Bank 4)
Value RAM 2 Index 50h - 5Ah (auto-increment) (BANK 5)
ADDRESS A6-A0
AUTO-INCREMENT
DESCRIPTION
50h
5VSB reading
51h
VBAT reading
52h
Reserved
53h
Reserved
54h
5VSB High Limit
55h
5VSB Low Limit.
56h
VBAT High Limit
57h
VBAT Low Limit
Winbond Test Register -- Index 50h (Bank 6)
FAN 1 Pre-Scale Register--Index00h(Bank 0)
Power on default [7:0] = 0000-0001 b
BIT
NAME
READ/WRIT
E
DESCRIPTION
7 PWM_CLK_SEL1 Read/Write PWM Input Clock Select. This bit select Fan 1 input
clock to pre-scale divider.
0: 24 MHz
1: 180 KHz
6-0 PRE_SCALE1[6:0] Read/Write
Fan 1 Input Clock Pre-Scale. The divider of input
clock is the number defined by pre-scale. Thus, writing
1 transfers the input clock directly to counter. The
maximum divider is 128 (7Fh).
01h : divider is 1
02h : divider is 2
03h : divider is 3
:
:
PWM frequency = (Input Clock / Pre-scale) / 256