English
Language : 

W83697HG Datasheet, PDF (33/109 Pages) Winbond – WINBOND LPC I/O
W83697HF/ HG
6.5.4 The W83697HF temperature sensor 2 SMI# interrupt has two modes and it is
programmed at CR[4Ch] bit 6.
(1) Comparator Interrupt Mode
Temperature exceeding TO causes an interrupt and this interrupt will be reset by reading all the
Interrupt Status Register. Once an interrupt event has occurred by exceeding TO, then reset, if
the temperature remains above the THYST, the interrupt will occur again when the next conversion
has completed. If an interrupt event has occurred by exceeding TO and not reset, the interrupts
will not occur again. The interrupts will continue to occur in this manner until the temperature
goes below THYST. ( Figure 9.10 )
(2) Two-Times Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will also
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status
Register. Once an interrupt event has occurred by exceeding TO , then reset, if the temperature
remains above the THYST , the interrupt will not occur. (Figure 9.11 )
TOI
THYST
SMI#
TOI
THYST
*
*
**
SMI#
*
*
*
*
*Interrupt Reset when Interrupt Status Registers are read
Figure 9.10
Figure 9.11
- 30 -