W741C260 Datasheet, PDF (73/92 Pages) Winbond – 4-BIT MICROCONTROLLER
W741C260
Instruction Set Table 2, continued
MOV TM0H, R
Move R contents to TM0H
Machine code:
Machine Cycle:
Operation:
Description:
MOV TM1, #I
Machine Code:
Machine Cycle:
Operation:
Description:
MOV TM1L, R
00010100
1 R6 R5 R4 R3 R2 R1 R0
1
TM0H ← (R)
The contents of the data memory location addressed by R6 to R0 are
loaded into the TM0H.
Timer 1 set
00010001
I7 I6 I5 I4 I3 I2 I1 I0
1
Timer 1 set
The data specified by I7 to I0 is loaded to the Timer 1 to start the timer.
Move R contents to TM1L
Machine Code:
Machine Cycle:
Operation:
Description:
00010101
0 R6 R5 R4 R3 R2 R1 R0
1
TM1L ← (R)
The contents of the data memory location addressed by R6 to R0 are
loaded into the TM1L.