English
Language : 

W741C260 Datasheet, PDF (72/92 Pages) Winbond – 4-BIT MICROCONTROLLER
W741C260
Instruction Set Table 2, continued
MOV SEF, #I
Set/Reset STOP mode wake-up Enable Flag for port RC
Machine Code:
01010010
0 0 0 0 I3 I2 I1 I0
Machine Cycle:
Operation:
1
Set/reset STOP mode wake-up enable flag for port RC
Description:
MOV TM0, #I
Machine Code:
Machine Cycle:
Operation:
Description:
MOV TM0L, R
Machine Code:
The data specified by I cause a wake-up from the STOP mode. The falling-
edge signal on port RC can be specified independently.
I0 to I3
I0 = 1
I1 = 1
I2 = 1
I3 = 1
Falling edge signal on port RC
RC0
RC1
RC2
RC3
Timer 0 set
00010000
I7 I6 I5 I4 I3 I2 I1 I0
1
Timer 0 set
The data specified by I7 to I0 is loaded to the Timer 0 to start the timer.
Move R contents to TM0L
00010100
0 R6 R5 R4 R3 R2 R1 R0
Machine Cycle:
1
Operation:
Description:
TM0L ← (R)
The contents of the data memory location addressed by R6 to R0 are
loaded into the TM0L.
- 72 -