English
Language : 

W972GG8JB-3-TR Datasheet, PDF (66/87 Pages) Winbond – 32M 8 BANKS 8 BIT DDR2 SDRAM
W972GG8JB
10.12 AC Input Test Conditions
Input reference voltage
VREF
0.5 x VDDQ
V
1
Input signal maximum peak to peak swing
VSWING(MAX)
1.0
V
1
Input signal minimum slew rate
SLEW
1.0
V/nS
2, 3
Notes:
1. Input waveform timing is referenced to the input signal crossing through the VIH/IL(ac) level applied to the device under test.
2. The input signal minimum slew rate is to be maintained over the range from VREF to VIH(ac) min for rising edges and the
range from VREF to VIL(ac) max for falling edges as shown in the below figure.
3. AC timings are referenced with input waveforms switching from VIL(ac) to VIH(ac) on the positive transitions and VIH(ac) to
VIL(ac) on the negative transitions.
10.13 Differential Input/Output AC Logic Levels
PARAMETER
AC differential input voltage
AC differential cross point input voltage
AC differential cross point output voltage
SYM.
VID (ac)
VIX (ac)
VOX (ac)
MIN.
0.5
0.5 x VDDQ - 0.175
0.5 x VDDQ - 0.125
MAX.
VDDQ + 0.6
0.5 x VDDQ + 0.175
0.5 x VDDQ + 0.125
UNIT
V
V
V
NOTES
1
2
3
Notes:
1. VID (ac) specifies the input differential voltage |VTR -VCP | required for switching, where VTR is the true input signal (such
as CLK, DQS) and VCP is the complementary input signal (such as CLK , DQS ). The minimum value is equal to VIH (ac) -
VIL (ac).
2. The typical value of VIX (ac) is expected to be about 0.5 x VDDQ of the transmitting device and VIX (ac) is expected to track
variations in VDDQ. VIX (ac) indicates the voltage at which differential input signals must cross.
3. The typical value of VOX (ac) is expected to be about 0.5 x VDDQ of the transmitting device and VOX (ac) is expected to
track variations in VDDQ. VOX (ac) indicates the voltage at which differential output signals must cross.
VSWING(MAX)
ΔTF
VREF - VIL(ac) max
Falling Slew =
ΔTF
VDDQ
VIH(ac) min
VIH(dc) min
VREF
VIL(dc) max
VTR
VIL(ac) max
VSS
VCP
ΔTR
VIH(ac) min - VREF
Rising Slew =
ΔTR
VDDQ
VID
VSSQ
Crossing point
VIX or VOX
Figure 28 – AC input test signal and Differential signal levels waveform
- 66 -
Publication Release Date: Dec. 03, 2012
Revision A03