W949D6DB Datasheet, PDF (35/60 Pages) Winbond – Standard Self Refresh Mode
W949D6DB / W949D2DB
8.5.11 Burst Terminate of Read
The BURST TERMINATE command is used to truncate read bursts (with Auto Precharge disabled).
The most recently registered READ command prior to the BURST TERMINATE command will be
truncated. Note that the BURST TERMINATE command is not bank specific.
This command should not be used to terminate write bursts.
CK
CK
CKE
CS
(High)
RAS
CAS
WE
A0-An
BA0,BA1
= Don't Care
8.6 Write
The WRITE command is used to initiate a burst write access to an active row, with a burst length as set
in the Mode Register. BA0 and BA1 select the bank, and the address inputs select the starting column
location. The value of A10 determines whether or not Auto Precharge is used. If Auto Precharge is
selected, the row being accessed will be precharged at the end of the write burst; if Auto Precharge is
not selected, the row will remain open for subsequent accesses.
8.6.1 Write Command
CK
CK
CKE
CS
(High)
RAS
CAS
WE
Address
A10
BA0,BA1
CA
Enable AP
AP
Disable AP
BA
= Don't Care
BA = Bank Address
CA = Column Address
AP = Auto Precharge
- 35 -
Publication Release Date: Oct. 08, 2014