Note No.
Parameter
P14 Sharpness control range
TA1316AN
Test Conditions
SW mode
SW1 SW2 SW3 SW56
Test Method (test conditions: VCC = 9 V/2 V, Ta = 25° ± 3°C)
B
B
A
ON (1) Input sine wave (frequency variable) to TPA.
(2) Set pin 3 amplitude to 20 mVP-P.
(3) Set UNI-COLOR to maximum (1111111), SHR-TRACKING to SRT-GAIN minimum (11), APACON peak
frequency (APACON PEAK f0) to 15 M (00) and color detail enhancer (CDE) to center (10).
(4) Set picture mute to off (P-MODE: Normal1 (000)) and monitor pin 43.
(5) Set picture sharpness (PICTURE-SHARPNESS) to center (1000000) and measure amplitude V100 when
input frequency is 100 kHz.
(6) Set PICTURE-SHARPNESS to maximum (1111111) and measure amplitude VMAX00 when input frequency is
FAP00. Calculate GMAX00 using the following formula.
(7) Set PICTURE-SHARPNESS to minimum (0000000) and measure amplitude VMIN00 when input frequency is
FAP00. Calculate GMIN00 using the following formula.
(8) Set APACON PEAK f0 to 8.8 M (01) and measure amplitudes VMAX01 and VMIN01 as in steps (6) and (7)
when input frequency is FAP01. Calculate GMAX01 and GMIN01 using the following formulae.
(9) Set APACON PEAK f0 to 7.5 M (10) and measure amplitudes VMAX10 and VMIN10 as in steps (6) and (7)
when input frequency is FAP10. Calculate GMAX10 and GMIN10 using the following formulae.
(10) Set APACON PEAK f0 to 5 M (11) and measure amplitudes VMAX11 and VMIN11 as in steps (6) and (7) when
input frequency is FAP11. Calculate GMAX11 and GMIN11 using the following formulae.
GMAX*** = 20 × "og (VMAX*** ÷ V100) [dB]
GMIN*** = 20 × "og (VMIN*** ÷ V100) [dB]
*: When using a spectrum analyzer for monitoring, measure gain for low frequency.
65
2002-10-04