English
Language : 

SN74AUP1G80_17 Datasheet, PDF (8/38 Pages) Texas Instruments – Low-Power Single Positive-Edge-Triggered D-Type Flip-Flop
SN74AUP1G80
SCES593F – JULY 2004 – REVISED JULY 2017
www.ti.com
Timing Requirements (continued)
over recommended operating free-air temperature range, TA = –40°C to +85°C (unless otherwise noted) (see Figure 3)
VCC
MIN
TYP(1) MAX UNIT
0.8 V
6.7
3.4
1.2 V ± 0.1 V
2.4
1.5 V ± 0.1 V
1.2
Data high
ns
1.8 V ± 0.15 V
0.8
2.5 V ± 0.2 V
0.6
tsu
Setup time before CLK↑
3.3 V ± 0.3 V
0.8 V
0.4
8.9
3.4
1.2 V ± 0.1 V
2
1.5 V ± 0.1 V
1.3
Data low
ns
1.8 V ± 0.15 V
1.1
2.5 V ± 0.2 V
0.8
3.3 V ± 0.3 V
0.7
0.8 V
1
0
1.2 V ± 0.1 V
0
th
Hold time, data after CLK↑
1.5 V ± 0.1 V
0
ns
1.8 V ± 0.15 V
0
2.5 V ± 0.2 V
0
3.3 V ± 0.3 V
0
6.8 Switching Characteristics: CL = 5 pF
over recommended operating free-air temperature range, CL = 5 pF (unless otherwise noted) (see Figure 3 and Figure 4)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST CONDITIONS
MIN TYP MAX UNIT
VCC = 0.8 V
TA = 25°C
TA = –40°C to +85°C
91
90
VCC = 1.2 V ± 0.1 V
TA = 25°C
TA = –40°C to +85°C
175
220
fmax
VCC = 1.5 V ± 0.1 V
VCC = 1.8 V ± 0.15 V
TA = 25°C
TA = –40°C to +85°C
TA = 25°C
TA = –40°C to +85°C
237
230
269
240
MHz
VCC = 2.5 V ± 0.2 V
TA = 25°C
TA = –40°C to +85°C
280
250
VCC = 3.3 V ± 0.3 V
TA = 25°C
TA = –40°C to +85°C
280
260
VCC = 0.8 V
TA = 25°C
17.2
VCC = 1.2 V ± 0.1 V
TA = 25°C
TA = –40°C to +85°C
3.2 7.1 14.9
2.7
16.3
VCC = 1.5 V ± 0.1 V
TA = 25°C
TA = –40°C to +85°C
1.9
5 9.8
2.1
10.3
tpd
CLK
Q
VCC = 1.8 V ± 0.15 V
TA = 25°C
TA = –40°C to +85°C
1.7 3.9 7.6 ns
1.6
8.1
VCC = 2.5 V ± 0.2 V
TA = 25°C
TA = –40°C to +85°C
1.4 2.8 5.3
1.2
5.6
VCC = 3.3 V ± 0.3 V
TA = 25°C
TA = –40°C to +85°C
1.2 2.2 4.1
1
4.4
8
Submit Documentation Feedback
Copyright © 2004–2017, Texas Instruments Incorporated
Product Folder Links: SN74AUP1G80