English
Language : 

MSP430F241X_11 Datasheet, PDF (70/107 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F241x, MSP430F261x
MIXED SIGNAL MICROCONTROLLER
SLAS541G -- JUNE 2007 -- REVISED MARCH 2011
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
12-bit DAC linearity specifications (see Figure 41)
PARAMETER
TEST CONDITIONS
Resolution
12-bit monotonic
VREF = 1.5 V
DAC12AMPx = 7, DAC12IR = 1
INL
Integral nonlinearity (see Note 1) VREF = 2.5 V
DAC12AMPx = 7, DAC12IR = 1
VCC
2.2 V
3V
MIN TYP MAX UNIT
12
bits
2.0 8.0 LSB
DNL
Differential nonlinearity
(see Note 1)
VREF = 1.5 V
DAC12AMPx = 7, DAC12IR = 1
VREF = 2.5 V
DAC12AMPx = 7, DAC12IR = 1
2.2 V
3V
0.4 1.0 LSB
VREF = 1.5 V
Offset voltage without calibration DAC12AMPx = 7, DAC12IR = 1
(see Notes 1 and 2)
VREF = 2.5 V
EO
DAC12AMPx = 7, DAC12IR = 1
VREF = 1.5 V
Offset voltage with calibration
DAC12AMPx = 7, DAC12IR = 1
(see Notes 1 and 2)
VREF = 2.5 V
DAC12AMPx = 7, DAC12IR = 1
2.2 V
3V
2.2 V
3V
21
mV
2.5
dE(O)/dT
Offset error temperature
coefficient (see Note 1)
2.2 V/3 V
30
V/C
EG
dE(G)/dT
Gain error (see Note 1)
Gain temperature
coefficient (see Note 1)
VREF = 1.5 V
VREF = 2.5 V
2.2 V
3V
2.2 V/3 V
3.50 % FSR
10
ppm of
FSR/C
tOffset_Cal
Time for offset calibration
(see Note 3)
DAC12AMPx = 2
DAC12AMPx = 3, 5
DAC12AMPx = 4, 6, 7
2.2 V/3 V
100
32 ms
6
NOTES:
1. Parameters calculated from the best-fit curve from 0x0A to 0xFFF. The best-fit curve method is used to deliver coefficients “a” and
“b” of the first-order equation: y = a + b  x. VDAC12_xOUT = EO + (1 + EG)  (VeREF+/4095)  DAC12_xDAT, DAC12IR = 1.
2. The offset calibration works on the output operational amplifier. Offset calibration is triggered setting bit DAC12CALON.
3. The offset calibration can be done if DAC12AMPx = {2, 3, 4, 5, 6, 7}. The output operational amplifier is switched off with
DAC12AMPx = {0, 1}. The DAC12 module should be configured prior to initiating calibration. Port activity during calibration may affect
accuracy and is not recommended.
DAC Output
RLoad =
CLoad = 100pF
AV CC
2
DAC VOUT
VR+
Ideal transfer
function
Offset Error
Positive
Negative
Gain Error
DAC Code
Figure 41. Linearity Test Load Conditions and Gain/Offset Definition
70
 POST OFFICE BOX 655303 DALLAS, TEXAS 75265