MSP430F241X_11 Datasheet, PDF (68/107 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F241x, MSP430F261x
MIXED SIGNAL MICROCONTROLLER
SLAS541G -- JUNE 2007 -- REVISED MARCH 2011
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
12-bit ADC temperature sensor and built-in VMID
ISENSOR
PARAMETER
Operating supply current into
AVCC terminal (see Note 1)
TEST CONDITIONS
REFON = 0, INCH = 0Ah,
ADC12ON = 1, TA = 25_C
VCC
2.2 V
3V
MIN TYP
40
60
MAX
120
160
UNIT
A
VSENSOR†
See Note 2
ADC12ON = 1, INCH = 0Ah,
2.2 V
986
TA = 0C
3V
986
mV
TCSENSOR†
2.2 V
3.55
ADC12ON = 1, INCH = 0Ah
3V
3.55
mV/C
tSENSOR(sample)†
Sample time required if channel
10 is selected (see Note 3)
ADC12ON = 1, INCH = 0Ah,
Error of conversion result  1 LSB
2.2 V
3V
30
30
s
IVMID
Current into divider at channel 11
(see Note 4)
ADC12ON = 1, INCH = 0Bh
2.2 V
3V
NA
NA A
VMID
AVCC divider at channel 11
ADC12ON = 1, INCH = 0Bh,
VMID is ~0.5 x VAVCC
2.2 V
3V
1.1 1.10.04
1.5 1.500.04
V
tVMID(sample)
Sample time required if channel ADC12ON = 1, INCH = 0Bh,
11 is selected (see Note 5)
Error of conversion result  1 LSB
2.2 V
3V
1400
1220
ns
† Limits characterized
NOTES: 1. The sensor current ISENSOR is consumed if (ADC12ON = 1 and REFON = 1) or if (ADC12ON = 1, INCH = 0Ah and sample signal
is high). When REFON = 1, ISENSOR is already included in IREF+.
2. The temperature sensor offset can be as much as 20_C. A single-point calibration is recommended to minimize the offset error
of the built-in temperature sensor.
3. The typical equivalent impedance of the sensor is 51 k. The sample time required includes the sensor-on time tSENSOR(on).
4. No additional current is needed. The VMID is used during sampling.
5. The on time tVMID(on) is included in the sampling time tVMID(sample); no additional on time is needed.