English
Language : 

MSP430F241X_11 Datasheet, PDF (20/107 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F241x, MSP430F261x
MIXED SIGNAL MICROCONTROLLER
SLAS541G -- JUNE 2007 -- REVISED MARCH 2011
calibration data stored in information memory segment A
Calibration data is stored for the DCO and for the ADC12. It is organized in a tag-length-value (TLV) structure.
NAME
TAG_DCO_30
TAG_ADC12_1
TAG_EMPTY
ADDRESS
0x10F6
0x10DA
--
TAGS USED BY THE TLV STRUCTURE
VALUE
DESCRIPTION
0x01
0x08
DCO frequency calibration at VCC = 3 V and TA = 25C at calibration
ADC12_1 calibration tag
0xFE Identifier for empty memory areas
LABELS USED BY THE ADC CALIBRATION STRUCTURE
LABEL
CONDITION AT CALIBRATION / DESCRIPTION
CAL_ADC_25T85
CAL_ADC_25T30
CAL_ADC_25VREF_FACTOR
CAL_ADC_15T85
CAL_ADC_15T30
CAL_ADC_15VREF_FACTOR
CAL_ADC_OFFSET
CAL_ADC_GAIN_FACTOR
CAL_BC1_1MHZ
INCHx = 0x1010; REF2_5 = 1, TA = 85C
INCHx = 0x1010; REF2_5 = 1, TA = 30C
REF2_5 = 1, TA = 30C
INCHx = 0x1010; REF2_5 = 0, TA = 85C
INCHx = 0x1010; REF2_5 = 0, TA = 30C
REF2_5 = 0, TA = 30C
External VREF = 1.5 V, fADC12CLK = 5 MHz
External VREF = 1.5 V, fADC12CLK = 5 MHz
--
CAL_DCO_1MHZ --
CAL_BC1_8MHZ --
CAL_DCO_8MHZ --
CAL_BC1_12MHZ --
CAL_DCO_12MHZ --
CAL_BC1_16MHZ --
CAL_DCO_16MHZ --
SIZE
word
word
word
word
word
word
word
word
byte
byte
byte
byte
byte
byte
byte
byte
ADDRESS OFFSET
0x000E
0x000C
0x000A
0x0008
0x0006
0x0004
0x0002
0x0000
0x0007
0x0006
0x0005
0x0004
0x0003
0x0002
0x0001
0x0000
brownout, supply voltage supervisor (SVS)
The brownout circuit is implemented to provide the proper internal reset signal to the device during power on
and power off. The SVS circuitry detects if the supply voltage drops below a user selectable level and supports
both supply voltage supervision (the device is automatically reset) and supply voltage monitoring (SVM) (the
device is not automatically reset).
The CPU begins code execution after the brownout circuit releases the device reset. However, VCC may not
have ramped to VCC(min) at that time. The user must ensure that the default DCO settings are not changed until
VCC reaches VCC(min). If desired, the SVS circuit can be used to determine when VCC reaches VCC(min).
digital I/O
There are up to eight 8-bit I/O ports implemented—ports P1 through P8:
D All individual I/O bits are independently programmable.
D Any combination of input, output, and interrupt conditions is possible.
D Edge-selectable interrupt input capability for all eight bits of ports P1 and P2.
D Read/write access to port-control registers is supported by all instructions.
D Each I/O has an individually programmable pullup/pulldown resistor.
D Ports P7/P8 can be accessed word-wise.
20