English
Language : 

MSP430F241X_11 Datasheet, PDF (42/107 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F241x, MSP430F261x
MIXED SIGNAL MICROCONTROLLER
SLAS541G -- JUNE 2007 -- REVISED MARCH 2011
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (continued)
main DCO characteristics
D All ranges selected by RSELx overlap with RSELx + 1: RSELx = 0 overlaps RSELx = 1, ... RSELx = 14
overlaps RSELx = 15.
D DCO control bits DCOx have a step size as defined by parameter SDCO.
D Modulation control bits MODx select how often fDCO(RSEL,DCO+1) is used within the period of 32 DCOCLK
cycles. The frequency fDCO(RSEL,DCO) is used for the remaining cycles. The frequency is an average equal
to:
DCO frequency
faverage
=
MOD
32 × fDCO(RSEL,DCO) × fDCO(RSEL,DCO+1)
× fDCO(RSEL,DCO)+(32−MOD) × fDCO(RSEL,DCO+1)
VCC
fDCO(0,0)
fDCO(0,3)
fDCO(1,3)
fDCO(2,3)
fDCO(3,3)
fDCO(4,3)
fDCO(5,3)
fDCO(6,3)
fDCO(7,3)
fDCO(8,3)
fDCO(9,3)
fDCO(10,3)
fDCO(11,3)
fDCO(12,3)
fDCO(13,3)
fDCO(14,3)
fDCO(15,3)
fDCO(15,7)
SRSEL
PARAMETER
Supply voltage
DCO frequency (0, 0)
DCO frequency (0, 3)
DCO frequency (1, 3)
DCO frequency (2, 3)
DCO frequency (3, 3)
DCO frequency (4, 3)
DCO frequency (5, 3)
DCO frequency (6, 3)
DCO frequency (7, 3)
DCO frequency (8, 3)
DCO frequency (9, 3)
DCO frequency (10, 3)
DCO frequency (11, 3)
DCO frequency (12, 3)
DCO frequency (13, 3)
DCO frequency (14, 3)
DCO frequency (15, 3)
DCO frequency (15, 7)
Frequency step between
range RSEL and RSEL+1
TEST CONDITIONS
RSELx < 14
RSELx = 14
RSELx = 15
RSELx = 0, DCOx = 0, MODx = 0
RSELx = 0, DCOx = 3, MODx = 0
RSELx = 1, DCOx = 3, MODx = 0
RSELx = 2, DCOx = 3, MODx = 0
RSELx = 3, DCOx = 3, MODx = 0
RSELx = 4, DCOx = 3, MODx = 0
RSELx = 5, DCOx = 3, MODx = 0
RSELx = 6, DCOx = 3, MODx = 0
RSELx = 7, DCOx = 3, MODx = 0
RSELx = 8, DCOx = 3, MODx = 0
RSELx = 9, DCOx = 3, MODx = 0
RSELx = 10, DCOx = 3, MODx = 0
RSELx = 11, DCOx = 3, MODx = 0
RSELx = 12, DCOx = 3, MODx = 0
RSELx = 13, DCOx = 3, MODx = 0
RSELx = 14, DCOx = 3, MODx = 0
RSELx = 15, DCOx = 3, MODx = 0
RSELx = 15, DCOx = 7, MODx = 0
SRSEL = fDCO(RSEL+1,DCO)/fDCO(RSEL,DCO)
VCC
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
3V
3V
2.2 V/3 V
MIN
1.8
2.2
3.0
0.06
0.07
0.10
0.14
0.20
0.28
0.39
0.54
0.80
1.10
1.60
2.50
3.00
4.30
6.00
8.60
12.0
16.0
SDCO
Frequency step between
tap DCO and DCO+1
SDCO = fDCO(RSEL,DCO+1)/fDCO(RSEL,DCO)
2.2 V/3 V
1.05
Duty cycle
Measured at P1.4/SMCLK
2.2 V/3 V
40
TYP MAX UNIT
3.6
3.6 V
3.6
0.14 MHz
0.17 MHz
0.20 MHz
0.28 MHz
0.40 MHz
0.54 MHz
0.77 MHz
1.06 MHz
1.50 MHz
2.10 MHz
3.00 MHz
4.30 MHz
5.50 MHz
7.30 MHz
9.60 MHz
13.9 MHz
18.5 MHz
26.0 MHz
1.55 ratio
1.08 1.12 ratio
50
60 %
42
 POST OFFICE BOX 655303 DALLAS, TEXAS 75265