English
Language : 

LM3S1H11 Datasheet, PDF (673/956 Pages) Texas Instruments – Stellaris® LM3S1H11 Microcontroller
Stellaris® LM3S1H11 Microcontroller
Bit/Field
5
4
3
2
Name
DCINT5
DCINT4
DCINT3
DCINT2
Type
R/W
R/W
R/W
R/W
Reset
0
0
0
0
Description
Digital Comparator Interrupt 5
Value Description
1 Resets the Digital Comparator 5 interrupt unit to its initial
conditions.
0 No effect.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
Digital Comparator Interrupt 4
Value Description
1 Resets the Digital Comparator 4 interrupt unit to its initial
conditions.
0 No effect.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
Digital Comparator Interrupt 3
Value Description
1 Resets the Digital Comparator 3 interrupt unit to its initial
conditions.
0 No effect.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
Digital Comparator Interrupt 2
Value Description
1 Resets the Digital Comparator 2 interrupt unit to its initial
conditions.
0 No effect.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
January 23, 2012
673
Texas Instruments-Production Data