English
Language : 

LM3S1H11 Datasheet, PDF (671/956 Pages) Texas Instruments – Stellaris® LM3S1H11 Microcontroller
Stellaris® LM3S1H11 Microcontroller
Bit/Field
21
20
19
18
Name
DCTRIG5
DCTRIG4
DCTRIG3
DCTRIG2
Type
R/W
R/W
R/W
R/W
Reset
0
0
0
0
Description
Digital Comparator Trigger 5
Value Description
1 Resets the Digital Comparator 5 trigger unit to its initial
conditions.
0 No effect.
When the trigger has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the trigger, it is important
to reset the digital comparator to initial conditions when starting a new
sequence so that stale data is not used.
Digital Comparator Trigger 4
Value Description
1 Resets the Digital Comparator 4 trigger unit to its initial
conditions.
0 No effect.
When the trigger has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the trigger, it is important
to reset the digital comparator to initial conditions when starting a new
sequence so that stale data is not used.
Digital Comparator Trigger 3
Value Description
1 Resets the Digital Comparator 3 trigger unit to its initial
conditions.
0 No effect.
When the trigger has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the trigger, it is important
to reset the digital comparator to initial conditions when starting a new
sequence so that stale data is not used.
Digital Comparator Trigger 2
Value Description
1 Resets the Digital Comparator 2 trigger unit to its initial
conditions.
0 No effect.
When the trigger has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the trigger, it is important
to reset the digital comparator to initial conditions when starting a new
sequence so that stale data is not used.
January 23, 2012
671
Texas Instruments-Production Data