TCM4300 Datasheet, PDF (44/69 Pages) Texas Instruments – Advanced RF Cellular Telephone Interface Circuit (ARCTIC )
At the same time, the interrupts DWBDINT and MWBDFINT are asserted. The interrupt rate is 800 µs
(8 bits/10 kHz). These interrupts are individually cleared when the WBD register is read by the
corresponding processor. They can also be cleared by their respective processor by writing a 1 to the
corresponding clear WBD bit.
There is one WBD control register. It can be written to by either processor port.
4.8 Wide-band Data Demodulator General Information
The WBDD recovers the transmitter clock from the data stream, which is Manchester encoded, and decodes
the data bits. Consideration at the system level is required to ensure data integrity.
The WBD stream carries with it a 10-kHz clock. The Manchester-coded data format contains a transition
at the middle of every bit-clock period, which aids in clock recovery. The polarity of the transition is
data-dependent. In a typical Manchester-coded WBD stream, a positive voltage for the first half of the data
sequence bit time followed by a negative voltage for the second half of the data sequence bit time represents
the value 0 in the data sequence. Likewise, a negative voltage followed by a transition to a positive voltage
represents the value 1 in the data sequence. This is illustrated in Figure 4–4. The WBD stream can also be
seen as the exclusive-OR of the clock and data sequence. The data sequence is in nonreturn to zero (NRZ)
format.
Data
Sequence
0
1
1
0
0
1
0
WBD
Stream
Recovered Clock
10 kHz
Figure 4–4. WBD Manchester-Coded Data Stream
4–9