English
Language : 

LM3S818 Datasheet, PDF (350/572 Pages) Bookham, Inc. – Microcontroller
Analog-to-Digital Converter (ADC)
Register 7: ADC Underflow Status (ADCUSTAT), offset 0x018
This register indicates underflow conditions in the sample sequencer FIFOs. The corresponding
underflow condition is cleared by writing a 1 to the relevant bit position.
ADC Underflow Status (ADCUSTAT)
Base 0x4003.8000
Offset 0x018
Type R/W1C, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
UV3
UV2
UV1
UV0
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO R/W1C R/W1C R/W1C R/W1C
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:4
3
2
1
0
Name
reserved
UV3
UV2
UV1
UV0
Type
Reset Description
RO 0x0000.000 Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
R/W1C
0
SS3 FIFO Underflow
When set, this bit specifies that the FIFO for Sample Sequencer 3 has
hit an underflow condition where the FIFO is empty and a read was
requested. The problematic read does not move the FIFO pointers, and
0s are returned.
This bit is cleared by writing a 1.
R/W1C
0
SS2 FIFO Underflow
When set, this bit specifies that the FIFO for Sample Sequencer 2 has
hit an underflow condition where the FIFO is empty and a read was
requested. The problematic read does not move the FIFO pointers, and
0s are returned.
This bit is cleared by writing a 1.
R/W1C
0
SS1 FIFO Underflow
When set, this bit specifies that the FIFO for Sample Sequencer 1 has
hit an underflow condition where the FIFO is empty and a read was
requested. The problematic read does not move the FIFO pointers, and
0s are returned.
This bit is cleared by writing a 1.
R/W1C
0
SS0 FIFO Underflow
When set, this bit specifies that the FIFO for Sample Sequencer 0 has
hit an underflow condition where the FIFO is empty and a read was
requested. The problematic read does not move the FIFO pointers, and
0s are returned.
This bit is cleared by writing a 1.
350
July 14, 2014
Texas Instruments-Production Data