Register 4: Raw Interrupt Status (RIS), offset 0x050
Central location for system control raw interrupts. These are set and cleared by hardware.
Raw Interrupt Status (RIS)
Base 0x400F.E000
Offset 0x050
Type RO, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
PLLLRIS CLRIS IOFRIS MOFRIS LDORIS BORRIS PLLFRIS
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:7
6
5
4
3
2
1
0
Name
reserved
PLLLRIS
CLRIS
IOFRIS
MOFRIS
LDORIS
BORRIS
PLLFRIS
Type
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
PLL Lock Raw Interrupt Status
This bit is set when the PLL TREADY Timer asserts.
Current Limit Raw Interrupt Status
This bit is set if the LDO’s CLE output asserts.
Internal Oscillator Fault Raw Interrupt Status
This bit is set if an internal oscillator fault is detected.
Main Oscillator Fault Raw Interrupt Status
This bit is set if a main oscillator fault is detected.
LDO Power Unregulated Raw Interrupt Status
This bit is set if a LDO voltage is unregulated.
Brown-Out Reset Raw Interrupt Status
This bit is the raw interrupt status for any brown-out conditions. If set,
a brown-out condition is currently active. This is an unregistered signal
from the brown-out detection circuit. An interrupt is reported if the BORIM
bit in the IMC register is set and the BORIOR bit in the PBORCTL register
is cleared.
PLL Fault Raw Interrupt Status
This bit is set if a PLL fault is detected (stops oscillating).
July 14, 2014