English
Language : 

RI-CTL-MB2B-30 Datasheet, PDF (35/40 Pages) Texas Instruments – Series 2000 Reader System
www.ti.com
3.1.2 Temperature
Operating temperature range: 0 to +70°C
Storage temperature range : –40 to + 85°C
Electrical Data
3.2 Electrical Data
3.2.1 Recommended Operating Conditions, Electrical Characteristics
3.2.1.1 ST22 – Supply
PARAMETER
VDC
DESCRIPTION
VCC2
Logic Supply Voltage
PDIS
IDC, ICC2
Power dissipated by the voltage
regulator
Supply Current
ICC2
VCC2
ICC2
Data retention input voltage
Data retention current
CONDITIONS
Connector ST22 pin 5 is used as
logic supply output. VDC = 7 to 25 V.
Jumper JP6 must be closed.
No external loads. Indicator LEDs
are on.
No external loads. Indicator LEDs
are on.
Output current if ST22 pin 5 is used
as external logic supply output. The
maximum power dissipation must
not be exceeded!
RESET = VRESOL (Reset active)(1)
MIN
TYP MAX UNIT
7
25 V
4.75
5.0
5.25 V
4W
120
200 mA
1A
2.7
3.0
VCC2
V
2
50 µA
(1) A reset can be initiated in one of three ways:
• Internally by the reset/watchdog circuit
• Externally by using the reset input (pin 3 of ST33)
• Externally by the RS-232 DTR signal (RI-CTL-MB2B only)
3.2.1.2 ST21 – RS-232-C Communication Interface
PARAMETER
VTXD
VRXD
VDTR
VDSR
VRXD_TRES
VDTR_TRES
Low
High
Low
High
DESCRIPTION
Output Voltage
Swing
Input voltage range
DTR input voltage
DSR Output voltage
CONDITIONS
TXD loaded 3 kΩ to Ground
DSR loaded 3 kΩ to Ground
RXD input threshold VCC2 = 5 V
DTR input threshold VCC2 = 5 V
ITXD
RRXD
IDTR
Short circuit current
TXD connected to ground, infinite
duration
DTR current
VDTR = 12 V
MIN
TYP.
MAX UNIT
=5
=9
V
–30
30
V
–30
30
V
3.5
4.1
VCC2
V
0.8
V
2.4
1.6
3.15
V
2.25
3.85
±18
mA
3
5
7 kΩ
3.6
3.8
4.1 mA
SCBU044 (11-09-21-077) – January 2008
Submit Documentation Feedback
Specifications
35